120VAC 24VDC 1500VA 1200W Extreme Temperature Network UPS for Industrial and Traffic Networks, 3U, Hardwire
Product Name |
Eaton Tripp Lite series SmartPro extreme temperature UPS
|
Catalog Number |
SMART1524ET
|
UPC |
037332241214
|
Product Length/Depth |
9.45 in
|
Product Height |
5.24 in
|
Product Width |
15.75 in
|
Product Weight |
32.41 lb
|
Compliances |
RoHS
TAA Compliant |
Certifications |
NOM
CSA certified UL 1778 |
Global Catalog |
SMART1524ET
|
Topology |
Line-interactive
|
Form factor |
Rackmount
|
Rack size |
3U
|
Package contents |
|
Input nominal voltage |
120 VAC
|
Nominal frequency |
50/60 Hz
|
Input frequency range |
50/60 Hz
|
Receptacle |
Hardwire
|
Output nominal voltage |
120V
|
Electric current - max |
22A
|
Runtime graph |
|
Battery type |
Valve Regulated Lead Acid (VRLA)
|
Runtime at half load |
113 min
|
Noise level |
52.4 dB maximum, front-side 1 meter
|
Relative humidity |
Up to 95% non-condensing
|
Front Panel LCD Display |
Four line text-based front panel LCD provides full access to UPS status, alarms, faults, events, settings and control options
|
Output Receptacles |
Hardwire
|
Output Receptacles Details |
Protected Line, Neutral and Ground hardwire output terminals; Includes strain relief
|
Product Features |
Individually Controllable Load Banks
Expandable Runtime |
Product Highlights |
Keeps power running during prolonged outages to allow time for safe system shutdown
Recommended for remote locations where temperatures range within -40°C and 80°C Protects equipment against blackouts, brownouts, overvoltages, surges and line noise Maintains continuous 120V nominal output during brownouts and overvoltages Optional WEBCARDLXMINI network interface supports Auto Probe feature Recommended for remote locations where temperatures range within -40°C and 80°C |
Nominal Output Voltage |
120V
|
Network Management Cards |
WEBCARDLXMINI
|
Network Management Cards Details |
Network management card optional
|
Output power factor |
0.8
|
Phase (input) |
Single-phase
|
Runtime at full load |
43
|
Communication interface |
Slot for SNMP / Web interface
DB9 Serial USB |
Typical Battery Runtime |
Expandable Runtime
|
Battery Charge |
Temperature compensated 2/4/6/8/10A selectable charging system; Battery temperature sensor cable included
|
Dc Voltage |
24V DC
|
Operating Temperature Range |
-40° to 176°F (-40° to 80°C)
|
Grounding Details |
Grounding lug connector provides a permanent ground connection for the UPS
|
Input Circuit Breakers |
30A breaker
|
Output Circuit Breakers |
30A breaker
|
High Voltage Transfer to Battery Power |
152V (default, adjustable from 120 to 152V)
|
Low Voltage Transfer to Battery Power |
88V (default, adjustable from 88 to 120V)
|
Undervoltage Correction |
Undervoltages from 88 to 102V are boosted by 8% (default, adjustable from 88 to 120V)
|
Application |
|
Switch configuration |
All three front-panel circuit breakers serve as power switches required to energize the UPS (DC INPUT, AC INPUT, AC OUTPUT); Three additional switches below the LCD provide SCROLL, ESCAPE and ENTER functions
|
AC suppression joule rating |
474
|
Housing material |
Steel
|
Output AC waveform (AC mode) |
Pure Sine Wave
|
Output AC waveform (battery mode) |
Pure Sine wave
|
Output Capacity (kVA) |
2
|
Output Capacity (kW) |
1.6
|
Output Capacity (VA) |
2000
|
Output Capacity Details |
Maximum output capacity is temperature dependent: 1600W (-40 to 55° C) / 1200W (55 to 75° C) and 1000W (75 to 80° C)
|
Operating Elevation |
|
Primary UPS Depth (mm) |
240
|
Primary UPS Height (mm) |
133
|
Primary UPS Width (mm) |
400
|
Audible Alarms |
Audible alarm reports Battery mode operation, Battery low status, Overload and UPS Fault conditions
|
Battery Start Capability |
Yes
|
Cooling Method |
High speed user-replaceable fan with dust filter
|
LED Indicators |
Set of 3 front panel LEDs report AC output status (green), Alarm condition (yellow) and Fault condition (red)
|
Output Voltage Regulation (Line Mode) |
120V (-14% / +8%) Factory setting, adjustable
|
Output Voltage Regulation(Battery Mode) |
120V (±4%)
|
Overvoltage Correction |
Overvoltages from 128 to 152V are reduced by 20% (default, adjustable from 120 to 144V)
|
Recommended Electrical Service |
120V AC
|
Storage Temperature |
-40° to 176°F (-40° to 80°C)
|
Included Mounting Accessory Description |
Set of two rackmount brackets support installation in 2 or 4 post racks
|
Input Connection Description |
Protected Line, Neutral and Ground hardwire input terminals; Includes strain relief
|
Input Dry Contact Ports |
1 set of input dry contacts generate an alarm of configurable input conditions when pins 1&2 are shorted; Rating: 300VDC/12A; Wiring Gauge: Up to 12AWG
|
Output Dry Contact Ports |
6 sets of output dry contacts support normally-open or normally-closed signaling of configurable UPS conditions; Rating: 300VDC/12A; Wiring Gauge: Up to 12AWG
|
Network Monitoring Port Description |
WEBCARDLXMINI network management card option supports operation from 0C to 70C as measured inside the UPS; Built-in USB and Serial ports support UPS configuration via Windows Hyperterminal session
|
Voltage Regulation Description |
Corrects brownouts and overvoltages from 88 to 152V to 120V nominal (factory default)
|
Maximum Input Amps |
22
|
Minimum Required Rack Depth (cm) |
25.4
|
Minimum Required Rack Depth (inches) |
10
|
UPS Power Module Dimensions |
5.24 x 15.750 x 9.45
|
Power Mode Transfer Time |
UPS mode: 10ms (typical) / 12ms (max); Generator mode: 20ms (typical) / 22ms (max)
|
Connected Equipment Insurance |
$250,000 Ultimate Lifetime Insurance
|
EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
UPS Input Connection Type |
Hardwire
|
High Availability UPS Features |
Surge/noise protection
Automatic voltage regulation (AVR) |