550VA 300W Standby UPS - 10 NEMA 5-15R Outlets, 120V, 50/60 Hz, 5-15P Plug, ENERGY STAR, Desktop/Wall
| Product Name |
Eaton Tripp Lite series ECO UPS
|
| Catalog Number |
ECO550UPS
|
| UPC |
037332211064
|
| Product Length/Depth |
10.86 in
|
| Product Height |
7.36 in
|
| Product Width |
5.67 in
|
| Product Weight |
3.96 lb
|
| Compliances |
RoHS
FCC Class B ENERGY STAR certified |
| Certifications |
NOM
UL 1778 RETIE CSA certified |
| Global Catalog |
ECO550UPS
|
| Product Type |
UPS
|
| Topology |
Standby
|
| Form factor |
Desktop
|
| Rack size |
0U
|
| Package contents |
|
| Input nominal voltage |
120V AC
|
| Nominal frequency |
50/60 Hz
|
| Input frequency range |
50/60 Hz
|
| Receptacle |
|
| Output nominal voltage |
110 / 120V
|
| Electric current - max |
|
| Battery replacement |
IMPORTANT BATTERY REPLACEMENT INFORMATION > If your ECO550UPS has no battery access door, please contact a local electronics repair technician to source and install a matching replacement battery; If your ECO550UPS does have a battery replacement door and the original battery inside has a rating of 12V 3.6AH, please order Tripp Lite #RBC36H replacement battery
|
| Battery type |
Valve Regulated Lead Acid (VRLA)
|
| Runtime at half load |
5 min
|
| Relative humidity |
0-90% non-condensing
|
| Output Receptacles |
5-15R
|
| PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert
|
| Nominal Output Voltage |
110V
115V 120V |
| Network Management Cards Details |
Network management not supported
|
| Phase (input) |
Single-phase
|
| Runtime at full load |
1.2 min. (300W)
|
| Communication interface |
USB (HID enabled)
USB interface cable included |
| Battery Access |
Battery access door
|
| Dc Voltage |
12
|
| Operating Temperature Range |
32° to 104°F (0° to 40°C)
|
| Communications Cable |
USB interface cable included
|
| Input Circuit Breakers |
10A
|
| Load Management Receptacles |
The ECO Energy-Saving option will automatically POWER OFF three designated ECO outlets when the device connected to the MASTER load-sensing outlet is turned off (after approximately 3 minutes); ECO outlets will immediately POWER ON when the device connected to the MASTER load-sensing outlet begins consuming 21 watts or more (see manual)
|
| High Voltage Transfer to Battery Power |
145
|
| Low Voltage Transfer to Battery Power |
95
|
| Application |
|
| Switch configuration |
Switch controls power off/on status and ECO mode off/on status
|
| AC suppression joule rating |
316
|
| Housing material |
ABS
|
| Output AC waveform (AC mode) |
Pure sine wave
|
| Output AC waveform (battery mode) |
PWM sine wave
|
| Output Capacity (kVA) |
0.55
|
| Output Capacity (Watts) |
300
|
| Output Capacity Details |
4.6A @ 120V. (LINE MODE) 110%+/- 10% @ 5 minutes; (BATTERY MODE) 110% +/- 10% @ 5 seconds
|
| Operating Elevation |
Up to 3000m
|
| Primary UPS Depth (mm) |
185
|
| Primary UPS Height (mm) |
105
|
| Primary UPS Width (mm) |
110
|
| AC Suppression Response Time |
Instantaneous
|
| Audible Alarms |
Alarm remains silent in battery backup mode; Alarm sounds only to report low-battery, fault, overload and replace-battery conditions
|
| Battery Start Capability |
Cold-start operation supported
|
| Battery Replacement Description |
Replaceable internal batteries (see manual)
|
| LED Indicators |
1 Status LED reports operating mode, ECO mode and fault status
|
| Frequency Rating Details |
Output is regulated to +/-0.05Hz when input frequency exceeds +/-5Hz of nominal.
|
| Output Voltage Regulation (Line Mode) |
120V (+6%/-12%)
|
| Output Voltage Regulation(Battery Mode) |
120V (±10%)
|
| Rechargeable Battery |
6.5 hours (10% to 90%)
|
| Recommended Electrical Service |
15A 120V
|
| Storage Temperature |
5° to 113°F (-15° to 45°C )
|
| Nominal Voltage Details |
120V sinusoidal in line mode and 120V PWM in battery mode
|
| Voltage Regulation Description |
Input voltage range of 90 to 145
|
| WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications
|
| Maximum Input Amps |
10
|
| UPS Input Cord Length (m) |
1.5
|
| UPS Power Module Dimensions |
4.13 x 4.33 x 7.28
|
| Power Mode Transfer Time |
6 milliseconds typical (10 milliseconds max)
|
| Total Outlets |
10
|
| Output Capacity (VA) |
550
|
| Connected Equipment Insurance |
$100,000 Ultimate Lifetime Insurance
|
| EMI AC Noise Suppression |
EMI / RFI AC Noise Suppression
|
| UPS Input Connection Type |
5-15P
|
| Green Energy-Saving Features |
Greater than 95% efficiency - GREEN UPS
Power saving auto-shutoff ECO outlets |
| UPS Dataline Suppression |
1 line TEL/DSL or Ethernet
|
| UPS Output Receptacles |
5 UPS outlets, 5 surge-only outlets
|
| High Availability UPS Features |
Surge/noise protection
|
| Nominal Input Voltage Supported |
120V AC
|
Support from Eaton