2000W 230V Sinewave Inverter Charger. 6000W Peak Surge, 60A MPPT solar controller and 85A AC Charger. 24VDC input. Hardwire AC input/output. Wired Remote, BTS, Software Monitoring Capable.
| Product Name |
Eaton Tripp Lite series power inverter and charger
|
| Catalog Number |
APSWX2K24VMPPT
|
| UPC |
037332256454
|
| Product Length/Depth |
7.244 in
|
| Product Height |
20 in
|
| Product Width |
13.75 in
|
| Product Weight |
54.5 lb
|
| Compliances |
RoHS
CE Marked REACH UKCA |
| Certifications |
EN 61000
IEC 62109-2 IEC 62109-1 |
| Product Type |
Power inverter and charger
|
| Battery Charge |
Hybrid selectable 90A max charging system. 30A AC / 60A MPPT Solar Charger Controller
|
| Battery Pack Accessory (Optional) |
Wet/Gel/AGM/SLA/LFP (User Supplied)
|
| Expandable Battery Runtime |
User-supplied 24V DC battery system
|
| Expandable Runtime Description |
Runtime is expandable with any number of user-supplied wet-cell, gel-cell, or lithium (with integrated BMS) type batteries.
|
| High Voltage Transfer to Battery Power |
In 230V AC "auto" mode, inverter/charger switches to battery mode as line voltage increases to 264V+/-7V (user adjustable to 254V - see manual).
|
| Transfer Time (Line Power to Battery Mode) |
10 milliseconds
|
| Low Voltage Transfer to Battery Power |
In 230V AC "auto" mode, inverter/charger switches to battery mode as line voltage drops to 154V AC (user adjustable to 194V).
|
| Front Panel LCD Display |
Multi-function LCD displays Input, Output, Configuration, Battery Level, Charging Status, Load status. Left segment displays Input Voltage, Input Frequency, Battery Voltage, PV1 Voltage and Charger Current. Middle display: program settings, flash warning codes, fault codes, parallel system quantity (if configured). Right display segment displays Output Voltage, Output Frequency, Load Percentage, Load Current (VA), Load (watts), DC Discharge Current. Graphical icons for battery and load level (0-24%, 25%-49%, 50-74%, 75-100%), operation mode, and mute operation.
|
| Amperage Rating |
12
|
| Audible Noise |
60dB front side @ 1 meter
|
| Continuous Output Capacity (Watts) |
2000
|
| Cooling Method |
Thermal-controlled fan system
|
| DC System Voltage (VDC) |
24
|
| Frequency Compatibility Details |
47-65Hz
|
| Front Panel LEDs |
3 LEDs for Operation (Green), Charge (Amber), Fault (Red) Alarm Status. See manual for sequences.
|
| Generator Start Compatibility |
Contact relay signal (NO and NC) contacts
|
| Grounding |
Main grounding lug connects inverter/charger to earth or vehicle chassis ground
|
| Input Connection Type |
DC INPUT: Set of DC bolt-down terminals. AC/PV INPUT: Hardwire via built in terminal strip with cover plate
|
| LED Indicators |
3 LEDs for Operation (Green), Charge (Amber), Fault (Red) Alarm Status. See manual for sequences.
|
| Operating Elevation |
0-6562 ft. (0-2000 m)
|
| Operating Temperature |
0° to 50°C
|
| Output Capacity (Watts) |
2000
|
| Output Dry Contact Ports |
Normally open dry contacts provide 5 output alerts for UPS Fault, Overload, AC Fault, Battery Low voltage
|
| Output Frequency Regulation |
50/60Hz. Battery Mode: 50/60Hz +/- 0.3 Hz
|
| Output Voltage Regulation |
LINE POWER (AC): Maintains 220/230/240V nominal sine wave output from line power source. INVERTER POWER (AC): Maintains sine wave output voltage of 220/230/240 VAC (+/-10%).
|
| Peak Output Capacity (Watts) |
4000
|
| Power Cord Jacket Type |
SJT
|
| Frequency Compatability |
50/60 Hz
|
| Recommended Electrical Service |
230VAC 30A input circuit breaker (40A for Max AC Charge rate usage). DC INPUT: Requires 24VDC input source capable of delivering the required amperage when used at full continuous capacity - DC requirements increase during overload and peak output operation). PV MPPT INPUT: 30-115VDC Input (145VDC Max Open Circuit Voltage) 1600W Max Solar Panel Configuration
|
| Relative Humidity |
0-95% non-condensing
|
| Solar Panel |
Non-isolated system. Compatible with Mono-crystalline, Poly-crystalline with Grade A rating, and CIGS solar panels.
|
| Storage Temperature Range |
-15° to 60°C
|
| Switches |
3 position on/off/bypass switch. 4 push buttons up/down/left,right/enter. Remote control provides distant on/off control and monitoring of the inverter system when used in conjunction with included remote accessory.
|
| Voltage Compatibility (VDC) |
24
|
| Total outlets |
3
|
| Material |
Metal
|
| Output Receptacles |
Hardwire
C13 |
| Package Contents |
APSWX2K24VMPPT Sine Wave Solar Inverter/Charger
Owner's manual Wired on/off remote |
| Input Nominal Voltage |
220 VAC
230 VAC 240 VAC |
| Product Features |
Pure Sine Wave Output
Expandable Runtime DC INPUT: Set of DC bolt-down terminals. AC/PV INPUT: Hardwire via built in terminal strip with cover plate |
| Product Highlights |
Auto-transfer switching option allows the unit to function as an extended-run UPS
Delivers pure sine wave 230V AC power from AC or DC sources. Built-in Maximum Power Point Tracking (MPPT) solar charge controller that optimizes power generation from the solar panels. Ideal for installation in rural or remote sites including residential, leisure, gas/oil and forestry Priority source selection alternates to deliver whichever power is optimal at the time |
| Nominal Output Voltage |
220V
230V 240V |
| Voltage Compatibility (VAC) |
220 VAC
230 VAC 240 |
Support from Eaton